User Interface

·  32-bit Windows application

·  Multi-Document Interface

·  toolbar:  quick access to frequently used commands

·  status bar:  technique and command prompt

·  pull-down menus

·  WYSIWYG graphics

·  comprehensive and context sensitive help

 

File Management

·  reopen saved data files

·  save data file

·  delete files

·  list data file

·  convert to text files:  for exporting data to other software, such as spreadsheets

·  text file format

·  print present data

·  print multiple data files

·  print setup

 

Setup

·  technique:  a large repertoire of electrochemical techniques

·  experimental parameters:  extremely wide dynamic range

·  system setup:  choice of communication port, line frequency, choice polarity of potential and current axis

·  hardware test:  digital and analog circuitry diagnostic test

 

Instrument Control

·  run experiment:  real time data display in most cases

·  pause/resume during run

·  stop running experiment

·  reverse scan direction during run:  for cyclic voltammetry

·  repetitive runs:  automatic data save, signal averaging, delay or prompt between runs, up to 999 runs

·  run status:   stir, purge, iR compensation, smooth after run, RDE and SMDE control status

·  macro commands:  edit, save, read, and execute a series of commands

·  open circuit potential measurement

·  iR compensation:  automatic and manual compensation, solution resistance, double layer capacitance and stability test

·  analog filter setting:  automatic or manual setting of potential, i/V converter, and signal filters

·  cell control:  purge, stir, cell on, SMDE drop collection, and pre-run drop knock

·  step functions:  initial and two step potentials, duration of steps and number of steps, particularly useful for electrode treatment

·  working electrode conditioning before running experiment:  programmable 3 steps

 ·  rotating disk electrode: rotation speed, on/off control during deposition, quiescent time, run, and between runs

·  stripping mode:  enable/disable, deposition potential and time, stir and purge conditions

Graphic Display

·  present data plot

·  3D surface plot: front, rear, side, top and bottom view

·  overlay plots:  several sets of data overlaid for comparison

·  add data to overlay:  adding data files to overlay plot

·  parallel plots:  several sets of data plotted side by side

·  add data to parallel:   adding data files to parallel plot

·  zoom in/out:  visually selected zoom area

·  manual results:  visually selected baseline

·  peak definition:  shape, width, and report options

·  Special Plots:  x-y, ip-v, ip-v1/2, Ep-log v, semilog plots, linear polarization resistance plot

·  graph options:  video or printer options, axis, parameters, baseline, results, grids, axis inversion, axis freeze, axis titles, data sets, XY scales, current density option, reference electrode, header, and notes

·  color and legend:  background, axis, grid, curves, legend size, thickness, and display intervals

·  font:  font, style, size and color for axis labels, axis titles, header, parameters, and results

·  copy to clipboard:  for pasting the data plot to word processors

 

Data Processing

·  smoothing:  5-49 point least square and Fourier transform

·  derivatives:  1st - 5th order, 5-49 point least square

·  integration

·  convolution:  semi-derivative and semi-integral

·  interpolation:  2´ - 64´ data interpolation

·  baseline correction:  visually selected baseline, slope and dc level compensation

·  baseline fitting and subtraction: selectable fitting function, polynomial order and potential range for best fitting and baseline subtraction; particularly useful for trace analysis

·  data point removing

·  data point modifying:  visual data point modification

·  background subtraction: difference of two sets of data

 ·  signal averaging

·  mathematical operations:  both X and Y data array

·  Fourier spectrum

 

Analysis

·  calibration curve: calculation and plot

·  standard addition: calculation and plot

·  data file report: analytical report from existing data files

·  time dependence report

·  corrosion rate calculation

 

CV Digital Simulator

·  fast implicit finite difference algorithm

·  reaction mechanisms: 10 predefined mechanisms (low end models); or any combination involving electron transfer, first- and second-order chemical reactions (high end models)

·  system: diffusive or adsorptive

·  maximum equations: 12

·  maximum species: 9

·  simulation parameters:  standard redox potentials, rate of electron transfer, transfer coefficient, concentration, diffusion coefficient, forward and reverse chemical reaction rate constants, temperature, electrode area, and experimental parameters

·  simultaneous display of voltammogram and concentration profiles

·  automatic search and determine over-determined equilibrium constants

·  dimensionless current

     ·  equilibrium data

Impedance Simulator and Fitting Program

·  visual entry of equivalent circuitry

·  automatic equivalent circuit parameters fitting

 

View

·  data information:  date, time, filename, data source, instrument model, data processing performed, header and notes

·  data listing:  data information and numerical data array

·  equations:  general equations and equations relating to various electrochemical techniques

·  SECM probe status: probe position and current display

·  clock

·  toolbar

·  status bar

 

Help

·  context sensitive help

·  help topics

·  about the application

 

System requirements

·  operating system:  Microsoft Windows 95 / 98 / NT / Me / 2000 / XP

    ·  serial communication port or USB port

 

 

 

Overlay plots.

Automatic ip ~ v1/2 plot.

Automatic semilog plot.

Concentration-time dependence plot.

Fourier spectrum.

Nyquist plot of impedance data.

 

More Screenshots

Main | Products | Download | Contact Us | © 2007 CH Instruments, Inc.